Heat Pump Thermostats
Upgrade your climate control with Keemeet, a leading manufacturer of heat pump thermostats. Our 2 stage and 3 stage heat pump thermostats are built for high-efficiency management of air source, geothermal, and multi-stage heat pumps.
Take full control of your heating, cooling, and auxiliary heat through a color touchscreen. With real-time tracking of temperature, humidity, and energy history, Keemeet makes it easier than ever to monitor system status and optimize your consumption. Enjoy a smarter, more precise, and more cost-effective way to manage your HVAC today!

Keemeet Heat Pump Thermostats
Features of Keemeet Heat Pump Thermostats
Widely System Support
From 3H/2C heat pumps to gas, electric, or conventional systems, it’s the only controller you need for complex multi-stage HVAC setups.
Color Touchscreen
The 3.5” TFT high-resolution display paired with a capacitive touch interface makes navigation effortless. It provides a premium, smartphone-like experience.
Programmable Scheduling
With 5+2, 7-day, and 24-hour modes, plus the flexibility of four or six events per day, the system ensures maximum comfort while save energy costs.
Multi-Language Support
With 9 languages built-in, this interface is ready for international markets, making it intuitive for users across different regions without custom firmware.
Frost Protection
Built-in logic prevents pipes from freezing and hardware from failing during extreme cold snaps, protecting the building’s infrastructure even when the user is away.
Integration Ready
Whether you need standard 2.4G Wi-Fi for residential apps or Modbus (RS485/TCP) for industrial BMS integration, this hardware is ready to plug into any ecosystem.
| Purpose of control | Up to 3H/2C, Gas / Electric / Heat Pump / Fossil Fuel / Conventional system |
| Supply voltage | 24VAC, 110VAC 50/60 hz |
| Relay rating | 110VAC @5 Amp 24VAC @1 Amp |
| Output relay | SPST - NO |
| Display | 320x480 pixels color TFT - capacitive touch |
| Operating temperature | 1° C- 85° C |
| WiFi | IEEE 802.11 b/g/n - 2.4GHZ |
| Communications | Modbus RTU, Modbus TCP |
| Displayed temperature resolution | 0.1°C |
| Wire size, terminals | Current ≤ 5 a - 1.5 mm², solid core wire |
| Smart schedule type | 7days, weekday/weekend, 24hours |
| Schedule | Up to seven different 4- or 6-event program |
| Floor limit range | 5°C/60°C |
| Standby consumption | ≤0.5 W |
| Security | WPA/WPA2 |
| Dimensions (w/h/d) | 96 * 86 * 32.5 (mm) |
| Weight | ≤200 g |
| Enclosure rating | IP 21 |
| Product material | PC + ABS plastic |
| Alexa, Google home | Yes(option) |
What are the benefits of using a heat pump thermostat?
Regular thermostats often struggle with the complexity of a heat pump. A heat pump thermostat is built to managing everything from defrost cycles and auxiliary heat to multi-stage (2H/3C) compressor logic. This ensures your system isn’t just running, but running at peak efficiency.
The biggest benefit is on your energy bill. By using precise staging logic and balance point control, these thermostats stop the system from jumping to expensive backup heat unless it’s necessary. This can shave up to 25% off your energy costs. On top of that, you get real-time status alerts and smart home integration (like Alexa or Wi-Fi apps), so you can manage your comfort from anywhere.

Why choose Keemeet Factory's Heat Pump Thermostats
As a professional thermostat manufacturer, Keemeet provides full production control and flexible branding solutions to help grow your business.
- 3 SMT Machines & 4 Assembly Lines
- In-house Aging & Packaging Facility
- 100% AOI Automated Testing
- Custom Branding (OEM)
- 10+ Years Global Logistics Experience
Yes. Most heat pumps need a thermostat rated specifically for them. You need dedicated O/B terminals for the reversing valve and auxiliary heat control; trying to use a basic furnace thermostat can tank your efficiency or even mess up the equipment.
For dual-fuel or electric backup, the thermostat has to handle multi-stage auxiliary heat. It should also have outdoor temperature lockout settings for your strip or fossil fuel heat, plus logic that keeps the backup heat from kicking in unless it’s actually needed.
Ducted systems usually run on standard low-voltage thermostats. However, ductless mini-splits often use their own proprietary controls or Wi-Fi adapters, so you’ll need to check if a third-party smart thermostat is even compatible before you buy.
Heat pump thermostats often use "ramped recovery" to bring the temperature up slowly. This protects the compressor and avoids jumping straight to expensive backup heat. Furnace thermostats, on the other hand, are basically just simple on/off switches.
We recommend “Auto.” This ensures the fan only runs during a call for heat or cool. Using “On” can lead to cold drafts and humidity problems since the fan stays spinning even when the system isn't actively conditioning the air.
Why Partner With Us
- Free consultation and equipment recommendation
- 13+ years of manufacturing experience
- Competitive B2B pricing with global shipping
- Custom OEM/ODM capabilities
- Comprehensive certification assistance
- Continuous innovation through R&D investment